ABSTRACT Polymer gel dosimeter have been developed as means of detecting and verifying an absorbed doses given to cancer patients for radiotherapy in the range (0-10Gy) as measured and verification dose distributions of three-dimensional (3D) treatments. This article reports on the dosimeter of a new N-isopropanol acrylamide NIPAM, high weight percent T%, %C the mass percent of all comonomer polymer gel formulation (6T%, 20C%), optimized for magnetic resonance imaging (MRI). The aim to investigated MR-based polymer gel dosimeter as a three-dimensional 3D dosimeter in IMRT. Magnetic resonance spin-spin relaxation rate images were acquired and, after calibration, converted to absorbed dose distribution. The dose maps were compared with the dose distribution calculated using ion chamber in one plan and radiographic film for two plans. The dosimeters were irradiated by 4, and 10MV photons for doses in the range (4–10) Gy. The multiecho sequence was used for the evaluation of T2 (spin-spin relaxation times) in the irradiated gel dosimeters. (%dd) percentage depth dose for (IMRT) intensity modulated radiation therapy / polymer gel & Magnetic resonance imaging = 5.7% at 5cm, other the average dose are 10.45 for dose profile, where %dd percentage depth dose for (IMRT) intensity modulated radiation therapy /ionization chamber and radiographic film(IC&RF) = 4.6% at 5cm other the average dose are 10.45 for dose profile. DVH dose volume histogram for polymer gel & magnetic resonance imaging = 94%, but DVH dose volume histogram for point by point ionization chamber and radiographic film = 86%.which lessince timing for protocol of integral part of verification radiation therapy.
El. Sayed, M., SAID, F., Dakrory, A., Hegazy, T., & Abdelghany, H. (2016). Dosimetric Verification of Dose Distribution as Three Dimensional Intensity Modulated Radiation Therapy based MRI Using Polymer Gel. The International Conference on Mathematics and Engineering Physics, 8(International Conference on Mathematics and Engineering Physics (ICMEP-8)), 1-11. doi: 10.21608/icmep.2016.29630
MLA
M. SH. El. Sayed; F. I. SAID; A. Z. Dakrory; T. M. Hegazy; H. A. Abdelghany. "Dosimetric Verification of Dose Distribution as Three Dimensional Intensity Modulated Radiation Therapy based MRI Using Polymer Gel", The International Conference on Mathematics and Engineering Physics, 8, International Conference on Mathematics and Engineering Physics (ICMEP-8), 2016, 1-11. doi: 10.21608/icmep.2016.29630
HARVARD
El. Sayed, M., SAID, F., Dakrory, A., Hegazy, T., Abdelghany, H. (2016). 'Dosimetric Verification of Dose Distribution as Three Dimensional Intensity Modulated Radiation Therapy based MRI Using Polymer Gel', The International Conference on Mathematics and Engineering Physics, 8(International Conference on Mathematics and Engineering Physics (ICMEP-8)), pp. 1-11. doi: 10.21608/icmep.2016.29630
VANCOUVER
El. Sayed, M., SAID, F., Dakrory, A., Hegazy, T., Abdelghany, H. Dosimetric Verification of Dose Distribution as Three Dimensional Intensity Modulated Radiation Therapy based MRI Using Polymer Gel. The International Conference on Mathematics and Engineering Physics, 2016; 8(International Conference on Mathematics and Engineering Physics (ICMEP-8)): 1-11. doi: 10.21608/icmep.2016.29630